OVERVIEW- ECO SERIES
 
Mahindra Powerol Home UPS is designed and developed using state – of – art Microcontroller & Digital Signal processing Based technology. Mahindra Powerol Home UPS set has been designed as a complete package to provide superior performance and reliability. It is compact and lighter than any other UPS in its class. It is ergonomically designed to give best operating environment for critical components to offer ultimate reliability with good aesthetics.
 
FEATURES / ADVANTAGES
 

Battery Low Alarm-     Low battery indication will blink with beep sound at 2 per sec, (backup LED on continuously ON).

 

Battery Low Shutdown- Low battery indication continuously glows (backup LED on continuously ON)

         

Overload Alarm - Overload alarm continuous glows for 12 sec with backup LED and overload indication. After 12 sec audio alarm off.

 

Battery Charging-  Main indication will glow during change over from backup to mains mode, after 3 to 4 sec, after 17 sec charging indication blinks continuously at rate of 2 blinks per second.

         

Battery Connect indication- Audio alarm (beep sound) for a moment.

 

Short circuit protection- Audio one beep sound for a moment. Backup LED glows continuously, no output voltage.

         

Battery Full Charge & Float Charge- When battery is fully charged, battery charging indication stops and after some time (This interval will vary according to battery float charge /discharge) it start blinking again. And this process will continue.

 

Vacation Mode- If there is No load in battery mode for more than 8 hours then HUPS will automatically will shut down to avoid deep discharge of battery.

         

Fuse Blown: If input AC fuse failed then continuous beep sound and mains LED glow.

 

Back-up  : Led glows when incoming mains is not available and the output is from HOME UPS.

         

Battery Low: LED glows while giving continuous beeps when the Battery is exhausted. After this indication system will switch off after few minutes.

 

Overload: LED glows to indicate either overload or short circuit on HOME UPS mode. The HOME UPS resets automatically and makes 5 attempts in case of Overload and 5 attempts in case of short circuit to turn on again, if the overload or short circuit continues even after these attempts, it turns off permanently and will turn on only after main switch is turned off and then turned on. In the event of unsuccessful attempts it automatically shuts down. During overload or short circuit this symbol glows and the buzzer gives intermittent beep. In case of short circuit at output, the Home UPS will turn off permanently after a few attempts. It can be reset by removing short circuit or reducing the Load applied and then switching off and on the UPS active switch.

         

Mains On : Mains LED glows when the mains CHARGE ON: LED Glows when incoming mains is available and side by side the charging of batteries is also taking place. This graphical symbol glows intermittently during charging and gets turned off when battery is fully charged.

 

Invertor Switch Off : If inverter switch is in OFF  then mains indication will blink and charger indication will continuous ON.

 